Valenjak Residential Tower
Residential
Residential
A residential high-rise in Tehran whose design balances architectural freedom, inclined columns, long cantilevers, a deep excavation and special seismic requirements.
The inclined columns at the entrance make the distribution of stiffness and strength irregular; some of them stay in the architecture while connection details limit or remove their part in the storey’s stiffness and strength.

35–40 m Excavation depth
The basement waffle slabs are thinner and give more clear height, and during top-down construction they act as stiff horizontal diaphragms, taking the soil’s lateral pressure and limiting the movement of the excavation walls.

62 Piles
The excavation built top-down with 62 shafts and 62 piles; the foundation is about 1.1 m thick.

≈ 20 cm Web openings
The services pass through the webs of the main beams, in openings of about 20 cm in the middle third of the beam and clear of its flanges, so structure and services fit together better.

≈ 40% Less joist steel
For its spans and a lighter seismic weight the superstructure has steel-deck slabs; the catalogue counts about 40% less joist steel than a composite slab among their advantages.

≈ 1.1 m Raft thickness
Besides their role in construction, the top-down piles reduce settlement and uneven movement and let the foundation’s thickness and reinforcement be optimised.